3.2 Programming menu A (key P1)- List of parameters
The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted; refer to paragraph ADVANCED
FUNCTIONS for more details
MENU A
ReclosingTim
PhotoAuto
Dead Man
Condominium
Photo Inv
Photo Test
Edge Test
Aux Light Time
Water Hammer
Sensor level
Sensor Inv
6-1622595
rev.06
13/01/2017
Timed closure of the gate (only from total or partial opening)
Auto
OFF: disabled
HH:MM:SS: time of persistence in opening position
Immediate closing after the intervention of the photocell (only from total or partial opening)
OFF: disabled
Reclose
ON: the gate closes 3 seconds after the contact between photocell has restored
Brake operation (for motors with high inertia).
OFF: disabled
1: electronic brake
Brake
2: activation of the contact on the auxiliary card for an external brake, active with still motor
3: activation of the contact on the auxiliary card for an external brake, active when motor is moving
"Dead Man" mode. The motor moves only by means of a permanent command
OFF: disabled
ON: enabled (WARNING: automatic motions are disabled)
Condominium function. The commands S.S. and PED allow only the opening of the gate
OFF: disabled
ON: enabled (WARNING: enable the "Automatic Re-Closure" in order to close)
Photocell intervention modality
OFF: the gate stays still until the obstacle is removed, and then opens completely
ON: the gate opens completely (this function does not apply in opening)
Functional test of the photocell; it is executed before the gate moves
OFF: disabled
ON: test activated (WARNING: supply the photocell with power as shown in the scheme)
Modality of operation of the safety edge (sensible edge)
OFF: the gate stops
Edge Inv
ON: the gate opens completely (this function does not apply in opening)
Functional test of the safety edge; it is executed before the gate moves
OFF: disabled
ON: test activated (WARNING: supply the safety edge with power as specified in the chap. 2.12)
Short flash before the motion of the gate
OFF: disabled
Pre-Blink
ON: enabled
Modality of functioning of the auxiliary output for lighting
OFF: courtesy light
Area light
ON: zone light (lit-off only when the gate is completely closed)
Auxiliary light's switching-off delay for lighting
OFF: Auxiliary light's output disabled
HH:MM:SS: switching-off delay - auxiliary light's output enabled
Programmed opening function
OFF: disabled
Clock
ON: the gate opens and stays open until the OPEN input is active
Water hammer before the gate opens
OFF: disabled
OP
XX,Xs: enabled. Adjustment of pressure time (in seconds) applied to the mechanical stop in closing
Functioning with encoder (only for motors equipped with a suitable encoder)
OFF: disabled
Encoder
ON: enabled (WARNING: the re-programming of the runs is needed)
Level of operation of the "motor still sensor" (with active encoder only)
OFF: sensor disabled
NNN : sensor enabled - adjustment of operation's sensitivity
Modality of operation of the "motor still sensor" (with active encoder only)
OFF: the gate stops
ON : reverses shortly in opening; opens completely in closing
EXIT