Allmatic CT INVERTER AM 설치 매뉴얼 - 페이지 6

{카테고리_이름} Allmatic CT INVERTER AM에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Allmatic CT INVERTER AM 12 페이지. Programmable control board for sliding gates with inverter technology

Allmatic CT INVERTER AM 설치 매뉴얼
3.2 Programming menu A (key P1)- List of parameters
The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted; refer to paragraph ADVANCED
FUNCTIONS for more details
MENU A
ReclosingTim
PhotoAuto
Dead Man
Condominium
Photo Inv
Photo Test
Edge Test
Aux Light Time
Water Hammer
Sensor level
Sensor Inv
6-1622595
rev.06
13/01/2017
Timed closure of the gate (only from total or partial opening)
Auto
OFF: disabled
HH:MM:SS: time of persistence in opening position
Immediate closing after the intervention of the photocell (only from total or partial opening)
OFF: disabled
Reclose
ON: the gate closes 3 seconds after the contact between photocell has restored
Brake operation (for motors with high inertia).
OFF: disabled
1: electronic brake
Brake
2: activation of the contact on the auxiliary card for an external brake, active with still motor
3: activation of the contact on the auxiliary card for an external brake, active when motor is moving
"Dead Man" mode. The motor moves only by means of a permanent command
OFF: disabled
ON: enabled (WARNING: automatic motions are disabled)
Condominium function. The commands S.S. and PED allow only the opening of the gate
OFF: disabled
ON: enabled (WARNING: enable the "Automatic Re-Closure" in order to close)
Photocell intervention modality
OFF: the gate stays still until the obstacle is removed, and then opens completely
ON: the gate opens completely (this function does not apply in opening)
Functional test of the photocell; it is executed before the gate moves
OFF: disabled
ON: test activated (WARNING: supply the photocell with power as shown in the scheme)
Modality of operation of the safety edge (sensible edge)
OFF: the gate stops
Edge Inv
ON: the gate opens completely (this function does not apply in opening)
Functional test of the safety edge; it is executed before the gate moves
OFF: disabled
ON: test activated (WARNING: supply the safety edge with power as specified in the chap. 2.12)
Short flash before the motion of the gate
OFF: disabled
Pre-Blink
ON: enabled
Modality of functioning of the auxiliary output for lighting
OFF: courtesy light
Area light
ON: zone light (lit-off only when the gate is completely closed)
Auxiliary light's switching-off delay for lighting
OFF: Auxiliary light's output disabled
HH:MM:SS: switching-off delay - auxiliary light's output enabled
Programmed opening function
OFF: disabled
Clock
ON: the gate opens and stays open until the OPEN input is active
Water hammer before the gate opens
OFF: disabled
OP
XX,Xs: enabled. Adjustment of pressure time (in seconds) applied to the mechanical stop in closing
Functioning with encoder (only for motors equipped with a suitable encoder)
OFF: disabled
Encoder
ON: enabled (WARNING: the re-programming of the runs is needed)
Level of operation of the "motor still sensor" (with active encoder only)
OFF: sensor disabled
NNN : sensor enabled - adjustment of operation's sensitivity
Modality of operation of the "motor still sensor" (with active encoder only)
OFF: the gate stops
ON : reverses shortly in opening; opens completely in closing
EXIT
ITA
ENG
FRA
ESP
DEU
POR
6 / 12