The operating hours counter for the
grease filters is set to 30 hours. This
can be lengthened or shortened to suit
the type of cooking you do. You can
choose from 20, 30, 40 or 50 hours.
– Select a short time if you roast or fry
a lot.
– If you use very little fat for cooking,
select a longer time.
– If, however, you only cook occasion-
ally we recommend that you select a
short time because grease which
has built up gradually over a long
period of time will harden on the
grease filters and make cleaning
more difficult.
Press the On/Off touch control to
switch the fan off.
Press the run-on option touch control
and the grease filter touch control at
the same time.
14
The indicator lamp above the grease fil-
ter touch control and one of the lamps
above the
/+ touch controls will flash.
The
/+ touch control lamps show the
time which has been set:
1st lamp from the left = 20 hours
2nd lamp from the left = 30 hours
3rd lamp from the left = 40 hours
4th lamp from the left = 50 hours
Use the
/+ touch controls to select
the desired time.
Confirm the selection by pressing
the grease filter touch control.
If the procedure is not confirmed
within 4 minutes of programming
the steps, the cooker hood will auto-
matically revert to the "old" data.