Bürkert 0400 Manual de instrucciones - Página 6

Navegue en línea o descargue pdf Manual de instrucciones para Unidad de control Bürkert 0400. Bürkert 0400 12 páginas.

Service life
High switching frequency and high pressures
reduce the service life
Permitted medium temperature depending on seal material
Seal material
NBR
FKM
Permitted media depending on seal material
Seal material
NBR
Neutral media such as compressed air, illuminating
gas, water, hydraulic oil, oils and grease without
additives
FKM
Oxygen, hot air, hot oils, oils with additives, Per
solutions
4.3 conformity
In accordance with the EC Declaration of conformity, the solenoid
valve Type 0400 is compliant with the EC Directives (if applicable).
6
Medium temperature
-10...+90 °C
-10...+100 °C
Permitted media
english
4.4 standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity (if applicable).
4.5 Type label (example)
Orifice
Circuit function
Type
0400 A 12,0 NBR
G1/2
P N 1 -16 bar
230V 50-60 Hz 8 W
00041404
W12MN
Identity number
Date of manufacture
Seal material
Body material
MS
Connection thread, Operating
pressure
Voltage, Frequency, Power
consumption
EC mark (if applicable)