Choosing A Mounting Location
The Door/Window Detector is suitable for mounting in dry interior locations only.
Decide which doors/windows are to be protected by Door/Window Detectors,
(usually the front and back doors as a minimum will have Door/Window Detectors
fitted). Additional detectors may also be fitted where required to other vulnerable
doors or windows, (e.g. garage, patio/conservatory doors etc).
Note: Take care when fixing the Detector to a metal frame, or mounting within 1m of
metalwork (i.e. radiators, water pipes, etc) as this could affect the radio range of the
device. If required, it may be necessary to space the magnet and detector away
from the metal surface using a plastic or wooden spacer to achieve the necessary
radio range.
Installation
1. Ensure that the system properly powered.
Factory default built in a CR2450 battery inside the detector and uses a Mylar
film to isolate battery from electric circuit of the detector. Remove the battery
Mylar film when ready to let the detector work.
If there is no battery inside the detector or need to replace a new battery please
insert the battery in 45° angle as below figure
2. Using the adhesive tape to fit detector on the door or window.
3. Fit the magnet to the moving part of the door/window opposite the detector
using the adhesive tape.
4. Ensure that the parallel gap between the magnet and detector is less than
20mm and that the matching line on the magnet is pointing towards and aligned
with the line on the detector. An alarm condition will be occurred if the gap is
greater than 35mm.
5. Remove the battery cover with the tamper switch not being pressed on the
detector (test mode), detach or close the magnet from the Detector, the LED on
the detector will illuminate.
6. After proper installation and test, put the battery cover back to the detector and
the detector enters the normal mode.
Note: After removing batteries, wait for 5 seconds to refit batteries.
Operation
1. The unit will stay "awake" for 5 minutes when power is first supplied to allow
time for configuration.
2. After the unit stays in sleep status, it can be woken up by pressing the tamper
switch continuously until the LED lights up once. The unit will enter sleep status
again after 10 seconds. If longer awake is desired, press tamper switch three
times within 1.5 seconds will prolong its awake period to 5 minutes.
3.
With the tamper switch not being pressed, the unit enters test mode, which
allows the user to make a test. Detach the magnet from the Detector, the red
indicator LED on the Detector will illuminate.
4.
When the tamper switch is pressed, the unit enters normal mode and the red
indicator LED on the Detector will not illuminate to conserve battery life when
the detector is triggered, (unless the battery is low).