Chromagic Technologies Z-Wave HSM02 Manual - Página 4
Navegue en línea o descargue pdf Manual para Sensores de seguridad Chromagic Technologies Z-Wave HSM02. Chromagic Technologies Z-Wave HSM02 5 páginas. Door/window detector
3-2 Wakeup Command Class
The unit stays in sleep status for the majority of time in order to conserve
battery power. However, it can be woken up at specified intervals by setting
WAKE_UP_INTERVAL_SET command by Z-Wave Controller. After the unit
wakes up, it will send Wakeup Notification Command to the node ID that
requires
to
be
reported
WAKE_UP_NO_MORE_INFORMATION command is received. The minimum
and maximum wakeup interval is 60 seconds and 194 days respectively.
Allowable interval among each wakeup interval is 1 second, such as 60, 61,
62 ....
Note: The default value is 1 day, which implies that the detector awakes and sends
the Wakeup Notification Command to the set node every hour.
4. Factory Default Setting
Command
Basic Set level
Period of Wake Up Notification
5. Command Classes
The Door/Window Detector supports Command Classes including...
*COMMAND_CLASS_SENSOR_BINARY
*COMMAND_CLASS_CONFIGURATION
*COMMAND_CLASS_WAKE_UP
*COMMAND_CLASS_MANUFACTURER_SPECIFIC
*COMMAND_CLASS_VERSION
*COMMAND_CLASS_ASSOCIATION
*COMMAND_CLASS_BATTERY
---For Control Other Devices---
*COMMAND_CLASS_BASIC
and
stay
awake
for
5
seconds
Default setting
99
1 day
Troubleshooting
Symptom
Cannot carry out
inclusion and association
if
no
LED not illuminating and
not working
Specifications
Battery
Range
Frequency Range
*Specifications are subject to change without notice
FCC ID: ZGXHSM02
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined
4
Possible Cause
Recommendation
Included a node ID
Exclude a node ID then
allocated by other
carry out inclusion and
Z-Wave Controller.
association with new
Controller.
Does not fit batteries or
Check if batteries are
run out of battery power.
fitted or replace a new
battery.
Does not fit batteries or
Check if batteries are
run out of battery power.
fitted or replace a new
battery.
Break down
Send it for repair and do
not open up the unit.
CR2450 Lithium Battery
Minimum 30 m line of sight
908.42 MHz (US) / 868.42 MHz (EU)