AQUAPHOR RO-102S Manual del usuario - Página 16

Navegue en línea o descargue pdf Manual del usuario para Sistemas de filtración de agua AQUAPHOR RO-102S. AQUAPHOR RO-102S 20 páginas. Reverse osmosis system
También para AQUAPHOR RO-102S: Manual del usuario (16 páginas)

AQUAPHOR RO-102S Manual del usuario
10. Replacing cartridges, Cont.
Replacing the conditioning cartridge K7М (K7*)
Set the shutoff valve on the connection node into the closed position; then open the clean water faucet to
1.
discharge pressure.
Press the button above the cartridge, and then rotate the used conditioning cartridge K7М (K7) in a
2.
clockwise direction to remove it.
Install a new conditioning cartridge.
3.
Set the shutoff valve on the connection node into the open position; then wait for all of the water to flow out
4.
from the storage tank through the clean water faucet.
Then close the clean water faucet.
5.
When the tank is filled, your RO is ready for operation.
6.
Make sure that RO is properly sealed.
7.
Replacing the membrane cartridge
Set the shutoff valve on the connection node into the closed position, and then open the clean water faucet
1.
to discharge pressure.
Press the button above the cartridge, and then rotate the used membrane cartridge in a clockwise direction
2.
to remove it.
Install a new membranecartridge in place of the removed one.
3.
Turn the shutoff valve on the connection node to the open position.
4.
Flush the water through RO for duration of approximately 1 hour.**
5.
Close the clean water faucet.
6.
When the tank is filled, RO is ready for operation.
7.
Make sure that RO is properly sealed.
8.
ATTENTION! To avoid any incorrect installation of the membrane cartridge and the resulting
loss of sealing of the RO connections, it is not recommended to dissemble it without a fully
qualified maintenance specialist. If the RO connections are leaking, immediately close the tap
on the connection unit and check the cartridges for correct installation.
* The K7 cartridge is not included in the water filter set and is sold separately.
** Depending upon storage, transportation and operation conditions, complete flushing of the membrane cartridge may take
up to 24 hours.
16
AQUAPHOR RO-101S, RO-102S