AQUAPHOR RO-202S Manual de instrucciones - Página 6
Navegue en línea o descargue pdf Manual de instrucciones para Sistemas de filtración de agua AQUAPHOR RO-202S. AQUAPHOR RO-202S 16 páginas. Reverse osmosis system
Installation of the connecting assembly*
• Turn water off at the mainline.
• Open the kitchen faucet to relieve pressure in
the water supply system.
• Unscrew the clamping nut of the flexible hose
from the cold water supply line to the faucet.
ATTENTION! The flexible hose may contain a
little water after depressurizing. When discon-
necting the flexible hose, use a 200 ml vessels
to drain the residual water.
• Screw the clamping nut of the connecting
assembly onto the thread of the cold water
supply.
• Screw the clamping nut of the flexible hose onto
the thread of the connecting assembly.
• Close the inlet cock of the connecting assembly
and supply water from the cold water supply
line to make sure that the connection is tight.
• Connect the corresponding JG tube.
ATTENTION! The end of the pipeline must be flat, where the connecting assembly is connected.
Do not use excessive force when tightening the clamping nut.
Otherwise, it will damage the gasket.
Fig. 5a
How to connect the JG tubes (Fig. 5a)
Pull the retaining clip out from under the plastic
sleeve, insert the pre-moistened end of the tube
into the plastic sleeve until it stops about 15 mm
deep and house the clip.
Check that the tube is tight. The tube should not be pulled out with a force of 8–10 kgf.
* The manufacturer reserves the right to use connecting assemblies and taps of a similar design. If you have any questions,
please, contact the service department.
6
The inlet cock
is in its closed position
Retaining clip
Connecting assembly
Cold water supply
Fig. 4
Fig. 5b
How to disconnect the JG tubes (Fig. 5b)
Pull the retaining clip out from under the plastic
sleeve and pull the tube out by pressing on the
end of the plastic sleeve.
Gasket