The refrigerated
equipment should never be installed:
a -near sources of heat such as radiators. direct or indirect sunlight or other equip-
ment which produces heat (photo F);
b -in
line with draughts coming from doors. windows
or ajr conditioning
systems
(photo F).
Do not close or obstruct
the ventilation
openings of the refrigeration
unit. because
this would stop the airflow which cools the refrigeration
unit causing a bad working.
OPERATION
START
After the refrigerated
equipment
has been installed, the power supply voltage has
been checked and the plug has been connected, switch on the unit. When the unit
has reached the working
tempe-
rature, put in the products alrea-
dy cooled.
Do not exceed
the
2/3 of the available
room
with
the product's
level. Leave some
room between the displayed pro-
ducts in order
to allow a good
airflow
and never obstruct
the
air intake situated
on the front
side.
G
~
PERIODICAL
I
MAINTENANCE
We suggest to carry out a tho-
rough cleaning of the cabinet once
a month for the good working,
the good preservation of the food
and the aesthetics preservation of the equipment. The periodical cleaning can be made
by qualified people, who should know the procedures
described
in this paragraph.
ATTENTION!
Before starting any cleaning operation
it is necessary to turn off the
equipment by the on/off red switch and to unplug or disconnect the equipment by the
generai power security switch of your shop. During the whole cleaning operation we
suggest to use working gloves to protect your hand alI the time.
To carry out the cleaning it is necessary:
I -to remove ali goods from the refrigerated unit and to keep them in a freedge or in a
refrigerated ambient suitable for their preservation;
2 -to unplug or disconnect the main on/off switch, disconnect the plug from the power
socket and wait until the equipment temperature reaches the room temperature;
3 -carefully
and thoroughly clean the display surface, the shelves, the glasses with spe-
cific cleaners for any surface. Never use abrasive substances, metal pads or other stuff
which can damage the unit.
4 -after
every cleaning operation it is necessary to rinse with warm water and dry the
unit with a soft cloth; in case the smaller evaporation tray is full, it will have to be emp-
tied and then put again in its originai position.
To clean the condenser unscrew the screws of the front panel.
5 -use a dry paint brush and/or a vacuum cleaner, removing ali dust. Pay attention not
to bend or damage the fins, the tubes or the blades of the fans. Never neglect this ope-
ration, as it is basic for the good working of the unit and to avoid possible breakings.
When the cleaning operation is over, make sure that everything is clean and dry before
connecting the equipment to the power supply again. When the unit reaches the correct
working temperature, it is possible to reload it. In case of long absences (i.e. holidays,
etc.) the unit has to be unplugged, emptied completely, cleaned and dried.
.Used
probe is not compatible
with the control;
.The
probe cable is interrupted
or short circuited;
.Faulty
sensor; take out the probe from the control
and verify the resistance (NTC;
25°C= IOKQ).
El BLINKS
faulty
evaporator
probe
or food
probe:
.Used
probe is not compatible with the control;
.The
probe cable is interrupted
or short circuited;
.Faulty
sensor. take out the probe from the control and verify the resistance (NTC:
25°C= IOKQ).
IA BLINKS
immediate
external
alarm:
.Check
the "Mutifunction"
input and the A4 and A7 parameters.
LO BLINKS
low temperature
alarm
(temperature
less than
SET-AL):
.Verify
the AL.Ad and AO parameters;
.The
alarm disappears as soon as the temperature
rises and ranges within the
selected limits.
HI BLINKS
high temperature
alarm
(temperature
higher
than SET+AH):
.Verify
the AH.AD
and AO parameters;
.The
alarm disappears as soon as the temperature
decreases and ranges within the
selected limits.
EE data acquisition
failure.
controller
RESET:
Set again the default parameters value. to restore correct operation.
Re-setting
the default values causes the loss of the modifìcations
relative to the working
parameters.
.switch-OFF
the control;
.Press the ~ and ~
buttons while switching on the control; "-CF" is displayed;
.After
a few seconds the instrument
enters the RESET ')hase and starts to work.
Ed BLINKS
timeout
defrost:
.Verify
the dt. dP and d4 parameters;
.Verify
defrost efficient.
dF BLINKS
defrost
currently
ON:
.It
is not an alarm signal. It simply indicates
a defrost cycle in progress.lt
appears only
if the parameter
d6=O.
~
,
,
x
'
'
"
(:,
'~',
'",
,
"
"
':::,
,
,
,
, , , ,
TEMPERATURE
The thermostat.
which
is situated
on the
electrical
control
panel. regulates the tem-
perature
into the equipment
and is usually
preset to +O/+6Co at the factory during the
testing phase.
A lower
performance
must be expected
from the refrigerated
unit when:
-the
equipment
is set on the lowest tem-
'
-,
perature
-the
equipment
is positioned
in an ambient with higher temperature
or relative
humidity than above indicated
-the amount of displayed products exceeds the maximum recommended and the pro-
per air circulation is prevented.
In those cases the goods are kept at higher temperatures.
the refrigerating
unit has
to run non-stop
and ice may form on the evaporator.
It is necessary therefore
to
turn the equipment off (approx 24 hours) to allow the melting of the ice.
DEFROSTING
The defrosting takes piace automatically
during the running of the unit. The defro-
sting cycles are 4 a day, last for about 40' each and are controlled
by a timer in the
electrical control
panel. During
the defrosting
phase the temperature
of the unit
could be altered, but when this cycle is over, in a short time the working
tempera-
ture will return to normal. The water from defrost is collected
in a tray equipped
with automatic evaporation
and a smaller tray underneath, which has to be emptied
manually when the automatic
evaporation
is not enough, especially during the sum-
mer months.
TECHNICAL
ASSISTENCE
(servicing)
If the equipment
does not run properly
or does not work at ali, in your own inte.
rest before calling for servicing, we suggest to check the following
points:
-if the plug is well inserted in the socket;
-if the power reachs the socket to which the equipment
is connected;
-if the thermostat
is set as recommended;
-if the network
voltage is the same as requested for the unit (+1- 6%).
DISMANTELLING
OF EQUIPMENT
The demolition
of the unit and the recovery
of the component
materials must be
carried out according to the regulation
in force in this matter. Considering
that the
equipment
is formed
by many different
materials (i.e. ABS with polyurethane
foam
for isolation. glass. stainless steel. aluminium. copper. etc.) and some of them are like
normal urban waste materials while other components.
as refrigeration
gas and oil.
MUST be given to a special recycling center.
REPLACEMENT
OF LAMPS
Disconnect
the main power
supply before fitting
or replacing the lamp. Slip the
ring nuts onto the fluorescent
lamp. Fit the lamp in the lamphoder
and turn it 90°.
Slide the ring nuts along the lamp until they rest on the lampholder
and turn them
clockwise (NPP and NPQ); screw down tightly (NPW).
NIGHT-BLIND
In case that the wall-cabinet
is equiped with a night-blind. we let you note that this
night-blind
is self-blocking. there are no hooks to block it. The night-blind
is equiped
with a spring and must always be pulled on. never left free. during the rolling phase.
The night-blind
can be stopped in any position. according to one.s wish.
ELECTRONIC THERMOSTAT
TEMPERATURE MODIFICATION
.Press
~
for seconds to display the selected parameter value;
.Press '* or ~
to reach the required temperature;
.Press
to confìrm.
INDICATION
ONTHE
DISPLAY
There are three LEDs of button
back-Iightening
which display the operating
status
of the instrument.
available only for TOP versions. For cheap versions. only one seg-
ment of the display signals compressor
ON.
.Button
Led ~
indicates compressor
ON
.Button
Led ~
indicates defrosting ON
.~
Button Led indicates presence of alarms.
T~e blinking status means that the corresponding
function
is delayed by a timed
routine.A
particular
blinking of the ~
button indicates that the manual request of
Continuous
Cycle is delayed by the compressor
timed routines.
ALARMSAND
SIGNALS
BLINKED
functioning
LED
.If a LED blinks it means that the corresponding
function
is delayed by a timed
routine. by another procedure
or inhibited by the digital input.
EO BLINKS
faulty
regulation
probe:
-
[ '}.
, ,.
"
\
"
~
\;::;~
"
\
'
,
.'
,