SAFETY OPERATION MANUAL INSTRUCTIONS
FORM 50073344
REVISION H
Installation Steps
1. Select the appropriate compression cable pull for the wire being pulled. Be sure to inspect
the compression cable pulls prior to use, to ensure no visual damage. BURNDY® does not
permit the use of damaged compression cable pulls.
2. Measure the insulated wire to determine strip length or use the table to determine the
appropriate insulation strip length of the wire. End of insulated wire should be lined up with
the "DO NOT CRIMP BEYOND" line on the barrel, which is the line closest to the lanyard.
3. Carefully remove the required amount of insulation. If wire is not stripped per the minimum
requirement and or the bare wire is damaged from stripping, BURNDY
use of the compression cable pullers. The maximum rated pull loads defined in the tables are
based on properly stripping the wire insulation and having no damaged wire strands.
•
Wire that is not stripped to the appropriate length may result in the bare wire not fully
inserting into the compression barrel sleeve and therefore having an inadequate
installation. BURNDY
does not permit the use of their cable pulls when wire is not fully
®
inserted, as this can result in a failure of the compression cable pulls.
•
Wire that is damaged during the wire stripping process may result in an inadequate
compression of the sleeve. BURNDY
wire is damaged, as this can result in a failure of the compression cable pulls.
4. Insert the wire fully into the appropriate compression cable pull barrel.
5. Installation Tooling Requirement:
•
With the use of a 444S or 644 series die-less installation tools, apply the proper number of
crimps to the barrel centered on the knurl bands. See table for the required number of
crimps per cable pull. If a barrel requires more than 1 crimp
•
Required to rotate each consecutive crimp 180 degrees.
•
Required to start your crimps from the knurl band closest to the lanyard, with each-
consecutive crimp toward the wire.
•
With the use of a PAT750-, Y750-, PAT46-, or Y46- installation tools, apply the proper
number of crimps to the barrel centered on the knurl bands. See table for proper number of
crimps. Crimps DO NOT have to be rotated with U-dies.
6. Once all the crimps have been properly applied, the compression grips are ready for use.
does not permit the
®
does not permit the use of their cable pulls if the
®
COMPRESSION CABLE PULLING GRIPS