Panasonic WV-SW316L Manual de instalación - Página 22
Navegue en línea o descargue pdf Manual de instalación para Videocámara Panasonic WV-SW316L. Panasonic WV-SW316L 50 páginas. Ip video cameras
También para Panasonic WV-SW316L: Especificación (2 páginas), Nota de integración (8 páginas)
c
Connect the alarm input/output cable.
<Ratings>
Terminal name
ALARM OUT, AUX OUT
Open
Close
ALARM IN, DAY/NIGHT IN Non-voltage make contact input (4 V DC - 5 V DC, internally pulled
OFF
ON
Note:
• Check if rating of an external device such as a sensor is applicable to the rating of this product
by referring to the provided operating instructions.
Specification of 4P alarm cable (accessory)
v
Connect a LAN cable (category 5e or better, straight, STP*) to the network connector.
* E model only
b
Connect the power cable.
• When using 12 V DC power supply*
Connect the output cable of the AC adaptor to the 2P power cable.
• When using PoE (IEEE802.3af compliant)
Connect a LAN cable (category 5 or better, straight, STP*
hub) and the network connector of the camera.
*1 FOR UL LISTED MODEL(S), ONLY CONNECT 12 V DC CLASS 2 POWER SUPPLY.
*2 E model only
IMPORTANT:
• Use all 4 pairs (8 pins) of the LAN cable.
• The maximum cable length is 100 m {328 feet}.
• Make sure that the PoE device in use is compliant with IEEE802.3af standard.
• When connecting both the 12 V DC power supply and the PoE device for power supply, PoE
will be used for power supply.
• When the LAN cable is disconnected once, reconnect the cable after about 2 seconds. When
the cable is quickly reconnected, the power may not be supplied from the PoE device.
22
SW316L
Ratings
Open collector output (maximum applied voltage: 20 V DC)
4 V DC - 5 V DC by internal pull-up
Output voltage 1 V DC or less (50 mA or less)
up)
Open or 4 V DC - 5 V DC
Make contact with GND (required drive current: 1 mA or more)
GND (black)
AUX OUT (gray) (Terminal 3)
ALARM OUT (red) (Terminal 2)
ALARM IN, DAY/NIGHT IN (green) (Terminal 1)
1
SW316L
SW316
SW316
2
) between a PoE device (such as a