HP StorageWorks 8/8 - SAN Switch Nota de publicación - Página 30

Navegue en línea o descargue pdf Nota de publicación para Interruptor HP StorageWorks 8/8 - SAN Switch. HP StorageWorks 8/8 - SAN Switch 43 páginas. Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
También para HP StorageWorks 8/8 - SAN Switch: Nota de publicación (30 páginas), Nota de publicación (29 páginas), Nota de publicación (32 páginas)

HP StorageWorks 8/8 - SAN Switch Nota de publicación
Bogus core_file created and transferred after the first reboot after a
firmwaredownload.
B-Series Multi-protocol (MP) Router blades in HP StorageWorks DC
SAN Backbone Director chassis may fail sysverification tests.
With a switch in Interop Mode 2 or 3, the Zoning configuration is not
being included in configupload.
FICON Channel continuously sends RRQ frames for approximately 20
seconds before aborting.
If QoS and Diff Serv are enabled, some FCIP tunnels may not come
online in the case of an 8 to 1 fan-in scenario.
Under rare conditions, fabric mode TopTalker monitor does not display
correct flow values.
Attempting to configure port mirroring on a director with both 4Gb
and 8Gb blades may result in a software Verify error.
In rare instances the Name Server DB is out of sync between FOS and
EOS switches in interop mode 3.
Seccertutil show does not display the contents of certificates with
.cer extension.
When resetting all the hosts on a blade or slotpoweroff on a blade,
HP StorageWorks 4/256 SAN Director CP reboots due to the Software
Watchdog detecting unexpected termination of the Name Server
daemon.
Fastboot causes unnecessary FFDC, ERROR, ..., libipadm:
em_AdmSwitchNameGet()
In some instances of congestion in the Ethernet network, the displayed
VE port utilization value is incorrect.
Reject code '0B' response to a QSA frame causes channel definition
errors.
30
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Rerun system verification.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Port disable/enable the VE-Port
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
After locating the device ID, disable
and then enable that device.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Only LDAP certificates with .cer ex-
tension is supported; so use the
--ldapcert option for importing
.cer certificates.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use portperfshow command.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Block off a badly misbehaving port
that is generating bad traffic on a
switch port that is putting a lot of
stress on the embedded port.