HP StorageWorks 8/8 - SAN Switch Nota de publicación - Página 31

Navegue en línea o descargue pdf Nota de publicación para Interruptor HP StorageWorks 8/8 - SAN Switch. HP StorageWorks 8/8 - SAN Switch 43 páginas. Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
También para HP StorageWorks 8/8 - SAN Switch: Nota de publicación (30 páginas), Nota de publicación (29 páginas), Nota de publicación (32 páginas)

HP StorageWorks 8/8 - SAN Switch Nota de publicación
When the switch name is set using CLI and then read using the Read
Port Address Name x'B2' command to the CUP Port x'FE' it returns the
switch name with a x'7F' attach after the last character in the Switch
Name.
A failed Pause frame (sent during firmwaredownload process in
Interop Modes 2 and 3), causes a fabric rebuild.
In some instances, HCL on an HP StorageWorks 8/40 SAN switch in
Interop Mode requires the use of the -o option.
A turboramtest failure does not fully disable the port on an HP
StorageWorks 8/80 SAN switch.
Web Tools: The HP StorageWorks DC04 SAN Director attention LEDs
on the switch view GUI window do not turn amber when blade needs
attention.
N-Port between AG and Edge Switch (300) may become stuck at E-
Port Unknown state.D
After multiple successive fastboots of an HP StorageWorks DC04 SAN
Director, there was a panic due to the zone daemon dying.
FICON PTP VTS Selective Resets and Aborted sequences caused by
incorrect entry into FICON tape read pipelining.
EX_Port fails to come online after downgrading firmware from Fabric
OS 6.x to 5.3 under certain conditions.
Tstimezone settings cannot be changed or restored with config-
download.
If a large number of EX_Ports are enabled at the same time, occasion-
ally some fail due to incompatible flow control parameters.
In some instances, portshow may display inaccurate port authentic-
ation description or state after a CP failover.
Internal server ports on embedded platform: traffic may stop due to
loss of buffer credit.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the -o option to override the co-
operative HCL feature.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the -o option.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable and then enable the port on
the AG to bring the port back online
as an N-Port.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Fastboot a single time.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Remove the ts.tz parameter in the
config file and then download.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Portdisable and then enable the
EX_Ports that failed.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
HP StorageWorks Fabric OS 6.2.0b release notes
31