Dickson SP125 Manual - Página 3

Navegue en línea o descargue pdf Manual para Registradores de datos Dickson SP125. Dickson SP125 9 páginas. Temperature data logger
También para Dickson SP125: Manual (3 páginas)

Dickson SP125 Manual

Getting Started

Install the DicksonWare™ Software.
Connect the cable (supplied with the software) to the logger and to a working UBS port on your
computer.
Click the Setup button. When the setup window appears, all fields should be automatically filled in,
this will confirm that DicksonWare™ has recognized the logger. Should all fields remain blank, refer to
"No Communication" in the Trouble Shooting section of this manual. Once DicksonWare™ recognizes
the logger, press the Clear button. This will delete all data currently stored.
The logger is now sampling and ready for use. The default sample interval is 1 minute. Verify that the
indicator light is flashing every 10 seconds. You may choose to change Default settings for sample
interval and start-date and time. When changing these settings, the logger will automatically go
through the clear process to accept your changes.
The LED will flash red when the unit is set-up for delayed start
NOTE: To conserve battery life when storing unit, press the Setup button and select the shortest Sample
Interval and Stop When Full in the Samples section or remove the battery.
DicksonWare™ Software Specifications
Microsoft Windows® compatible
Allows for simple viewing and zooming of logged data
Easy set-up of Dickson Data Loggers including:
User selectable sample intervals from 10 seconds to 24 hours
Display temperature in °C or °F
Delayed logger start times
Logger data capacity can be set to wrap data or stop when full
Allow for real time monitoring and graphing.
Effortless exporting of data and graphs to other software
Data can be viewed in tabular (numeric/table) or graphical formats
Fast downloading of logged data - 30 seconds (typical) from full logger
Even shows battery power status for battery operated loggers
Specifications:
Compatible With: Microsoft Windows® 95, 98, 2000, NT & XP
PC Requirements: PC w/486MHz or faster microprocessor, 16 MB RAM, 1 free USB root hub, CD
drive, VGA Monitor or better
Cable Type/Length: USB male series "A" plug to 5-pin male series "B" mini plug, 6' (2 meters)
Computer Interface: USB
DicksonWare™ Version Required (minimum): 10.0
Accessories
(for current pricing go to www.dicksondata.com or call 1-800-323-2448)
Software
DicksonWare™ Software and Serial Download Cable
Logger Calibration Software
Calibrations
NIST Traceable Calibration 3-pt (new unit)
NIST Traceable Calibration 1-pt (new unit)
A2LA Accredited Calibration 3-pt. (new unit)
Certificate of Validation
Rev. 04/08
Order #
A016
SW400
N300
N100
N400
N520