3. Inverter Operation
Connect the input and output terminals accurately. Turn on the
power using the ON / OFF switch on the front panel. In order to
avoid the protections resulted from the surge power, please turn on
AC loads one by one after the output of the inverter is normal.
Please check it as below:
Set the power switch to the „OFF‟ position. Insert the load‟s plug
into the inverter‟s output outlet.
Connect the protective grounding to the ground.
Make sure the fuse or breaker use between battery and inverter
is off.
Connect the battery („+‟ terminal with red line, „-‟with black line).
Do not connect them by contraries, or the power inverter will be
damaged.
Switch on the fuse or breaker. Switch the inverter to ON and then
turn on the loads one by one. Check the operation state of both
power inverter and loads. „Green‟ of the failure LED indicator
means the state is normal.
If there are different loads, it is suggested that turn on the load
with large startup current first, such as television, then turn on the
load such as lamp when the inverter works stable.
If the failure LED indicator is „Red‟ and the buzzer alarms or no
output when you turn on devices, switch off the loads and
power inverter immediately. Check the system by referring to the
troubleshooting guide. Turn on the devices again according to
the operation methods after the failure is removed.
4