Axor Citterio Showerpipe 180 1jet 39671009 Manual de instrucciones - Página 2

Navegue en línea o descargue pdf Manual de instrucciones para Sanitarios Axor Citterio Showerpipe 180 1jet 39671009. Axor Citterio Showerpipe 180 1jet 39671009 12 páginas.

EN
0 2
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
The arm of the shower head is intended only to hold the shower head. Do not load
it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be altered
if required. In this case, pay attention to the fact that a change of installation height
will also change the minimum height, and that the altered mounting dimensions must
be taken into consideration.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The mesh washer must be insert to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or/and can damage parts of the shower;
such caused faults voids all liability and guarantee claims.
⁄ The product is not designed to be used with steam baths!
⁄ If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
⁄ If the continuous water heater causes any problems, or you have different water
pressures you must install a water limiter to the cold supply, (ordered separately,arti-
cle number 97510000).
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
Thermal disinfection:
F A U L T
⁄ Insufficient water
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Spout temperature does not correspond with temperature
set
⁄ Temperature regulation not possible
⁄ Instantaneous heater didn't work with thermostat
A S S E M B L Y (see page 04)
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
150±12 mm
cold right - hot left
max. 70°C / 4 min
C A U S E
⁄ Supply pressure inadequate
⁄ Regulator filter dirty
⁄ Shower filter seal dirty
⁄ Backflow preventers dirty or leaking
⁄ Thermostat has not been adjusted
⁄ Hot water temperature too low
⁄ thermo cartridge calcified
⁄ Filters are dirty
⁄ check valve hasn't moved back
⁄ Flow limiter in handshower isn't removed
Do not use silicone containing acetic acid!
S A F E T Y F U N C T I O N (see page 06)
The desired maximum temperature for example max. 42º C can be pre-set
thanks to the safety function.
A D J U S T M E N T (see page 06)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
M A I N T E N A N C E (see page 07)
⁄ The check valves must be checked regularly according to DIN EN 1717
in accordance with national or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page 09)
F L O W D I A G R A M (see page 09)
 Overhead shower
 Hand shower
S P A R E P A R T S (see page 10)
S P E C I A L A C C E S S O R I E S (order as an extra)
tile-matching-disk Chrome Plated #95239000 (see page 10)
C L E A N I N G (see page 08)
O P E R A T I O N (see page 11)
To empty the overhead shower after use, hold it in a slightly inclined position.
R E M E D Y
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Clean filter in front of the mixer and on the MTC-thermo car-
tridge
⁄ Clean filter seal between shower and hose
⁄ Clean backflow preventers, exchange if necessary
⁄ Adjust thermostat
⁄ Increase hot water temperature to 42 ºC to 65 ºC
⁄ Exchange thermo cartridge
⁄ Clean the filter / exchange filter
⁄ Exchange check valves
⁄ Remove flow limiter