Navegue en línea o descargue pdf Nota de instalación para Interruptor Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion. Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion 36 páginas. Distributed forwarding card 4 for ws-x68xx, ws-x69xx, and select ws-x67xx modules
También para Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion: Nota de instalación (14 páginas), Manual de soluciones (17 páginas), Nota de instalación (46 páginas), Libro Blanco (19 páginas), Descripción (1 páginas), Boletín de productos (6 páginas), Aviso (4 páginas), Ficha de datos (9 páginas), Ficha de datos (18 páginas), Libro Blanco (18 páginas), Manual de configuración (8 páginas), Nota de instalación (28 páginas), Manual de solución de problemas (11 páginas), Nota de instalación (18 páginas), Manual del usuario (17 páginas), Nota de instalación (24 páginas), Manual (19 páginas)

Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion Nota de instalación
Vertical slots
Position the Ethernet module in the slot. (See
a.
module carrier with the slot guides on the top and bottom of the chassis slot.
b.
Carefully slide the Ethernet module into the slot until the EMI gasket along the right edge of the
module faceplate makes contact with the module in the slot adjacent to it and both ejector levers
have closed to approximately 45 degrees with respect to the Ethernet module faceplate. (See
Figure
Using the thumb and forefinger of each hand, grasp the two ejector levers and exert a slight pressure
c.
to the left, deflecting the module approximately 0.040 inches (1 mm) to create a small gap between
the module's EMI gasket and the module adjacent to it. (See
Caution
Do not exert too much pressure on the ejector levers because they can bend and be damaged.
While gently pressing on the ejector levers, simultaneously close them to fully seat the Ethernet
d.
module in the chassis backplane connector. The ejector levers are fully closed when they are flush
with the Ethernet module faceplate. (See
Tighten the two captive installation screws on the Ethernet module.
e.
Note
Verify that the Ethernet module STATUS LED is lit. Check the STATUS LED periodically. If the
f.
STATUS LED changes from orange to green, the module has successfully completed the boot
process and is now online. If the STATUS LED remains orange or turns red, the module has not
successfully completed the boot process and may have encountered an error.
Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note
OL-24918-02
23.)
Make sure that the ejector levers are fully closed before tightening the captive installation
screws.
Removing and Installing Ethernet Modules in the Chassis