Siemens SIMATIC S7-200 Manual - Página 24
Navegue en línea o descargue pdf Manual para Equipamiento industrial Siemens SIMATIC S7-200. Siemens SIMATIC S7-200 35 páginas. Ethernet gateway for simatic mpi/ profibus driver
También para Siemens SIMATIC S7-200: Manual (30 páginas), Manual del conductor (28 páginas), Manual (49 páginas), Manual (18 páginas), Manual del sistema (20 páginas)

Micro Automation Set 14
3.
Remove the write protection of the
MicroBox PC 420.
Open the MS DOS prompt and enter the
following command to
•
deactivate:
ewfmgr c: -commitanddisable
•
activate:
ewfmgr c: -enable
the write mode.
4.
The following network settings have to be
applied on the used network card of the
MicroBox PC 420:
•
IP address:
•
Subnet mask: 255.255.255.0
5.
Install SIMATIC NET Edition 2005.
6.
Install WinAC 2005 RTX.
•
7.
Open the Station Configuration Editor
(
) in the task bar
•
Change the station name to
"WinAC_Station"
•
Assign slot 2 to WinLC RTX
•
Add the "IE-General" module on slot
3
8.
Open the included WinAC project
"Set14_WinAC_V2-0.zip" on your
configuration PC using STEP 7 and make
the following settings in STEP 7:
•
Set the access point in "Set PG/PC
Interface" to "S7ONLINE
TCP/IP(Auto) network controller"
V2.0
Entry ID 21062588
192.168.2.140
05/18/05
Live Demo
24/35