Cisco NCS 4201 Manual de instalación - Página 31
Navegue en línea o descargue pdf Manual de instalación para Punto de acceso inalámbrico Cisco NCS 4201. Cisco NCS 4201 42 páginas.
Installing the Cisco NCS 4201
Perform the following procedure to ground the Cisco NCS 4201 using a 2-hole lug and the corresponding
mounting point. Most carriers require a minimum 6-AWG ground connection. Verify your carrier's requirements
for the ground connection.
Step 1
If your ground wire is insulated, use a wire-stripping tool to strip the ground wire to 0.5 inch ± 0.02 inch (12.7 mm ±0.5
mm) (the figure below).
Figure 24: Stripping a Ground Wire
Step 2
Slide the open end of your 2-hole ground lug over the exposed area of the ground wire.
Step 3
Using a crimping tool (as specified by the ground lug manufacturer), crimp the ground lug to the ground wire as shown
in figure below.
Figure 25: Crimping a Ground Lug on to the Ground Wire
Step 4
Use a Phillips head screwdriver to attach the 2-hole ground lug and wire assembly to the chassis with the 2 pan-head
Phillips head screws.
Step 5
Connect the other end of the ground wire to a suitable grounding point at your site.
Installing the Chassis Ground Connection
Cisco NCS 4201 Hardware Installation Guide
31