Internal Switches and

Internal Boards

Note
To reduce the risk of electric shock, fire or injury, do not
open the cabinet. To adjust the internal settings, refer to
qualified service personnel.

Internal switches

The following switches are located inside the unit, behind
the front panel.
b Headset microphone switch 2 (S6)
a Headset microphone switch 1 (S5)
c Internal main power switch
a Headset microphone switch 1 (S5)
Set the switch according to the type of microphone of the
headset connected to the INCOM connector on the front
panel of this unit.
CARBON: Carbon microphone (power supply, 20 dB
gain)
ECM: Electret condenser microphone (power supply, 40
dB gain)
DYNAMIC: Dynamic microphone (no power supply, 60
dB gain) (factory-setting)
b Headset microphone switch 2 (S6)
When the headset microphone switch 1 (S5) is set to
DYNAMIC, set this switch according to the type of output
of the headset microphone.
GND: Unbalanced type (factory-setting)
OPEN: Balanced type
ON
c Internal main power switch
When an abnormality has occurred and power cannot be
cut off with the POWER switch on the front panel, you
may turn off the unit using the internal main power switch.
When the switch is set to off, pressing the POWER switch
on the front panel does not turn on the unit.
Internal boards
The internal boards are located inside the unit, behind the
front panel.
Internal boards
AT
ON
For details on the internal boards, consult your Sony
service personnel.