10.0 Occupancy/Transponding Indication
The BXP88 can report occupancy and Transponding information via the LocoNet
connection or via direct output to a user created LED panel.
10.1 LocoNet Devices
The BXP88 provides occupancy and transponding messages to LocoNet that can
be used by computer software for a visual display of occupancy and transponding
status on the layout or to other devices on the layout. For instance layout control
software can use these messages to control signals on the layout via a Digitrax
SE8c. See the operating manual of your computer software or the SE8C for de-
tails on installation and operation.
10.2 LT5 Tester
The BXP88 provides two LT5 LED compatible outputs labeled "DS1-4 LEDS"
and "DS5-8 LEDS" and the supplied LT5 tester can be plugged in here to provide
visible detection section, power state and fault information for setup, debug and
running. This will help you with layout wiring and troubleshooting for transpon-
ding & detection.
LT5 Indications
Detection Section LED on Solid
Detection Section LED is Blinking Slow
Detection Section LED is Blinking Fast
Zone LED is on Solid
Zone LED off blinking on once repeating
every 2 seconds
Zone LED off blinking on twice repeating
every 2 seconds
Zone LED off blinking on 3 times repeating
every 2 seconds
Zone LED off blinking on 4 times repeating
every 2 seconds
Note: When a fault is detected a detection sections will show and report as Oc-
cupied and detection section LEDS will be lit. This is the default fail-safe logic,
reporting can be changed with OpSw 15.
© 2017 Digitrax, Inc.
Table 2: LT5 LED Indications
— 11 —
Meaning
Detection Section is Occupied
Detection Section is Occupied and Tran-
sponding
Detection Section is in Short Circuit
Normal Operation, no faults
Track Power is off, RailSync not detected
Rail A or Rail B unpowered
Internal Voltage Problem
LocoNet Error or Disconnected
www.digitrax.com