Cisco APIC M4 Manual de instalación y mantenimiento - Página 44

Navegue en línea o descargue pdf Manual de instalación y mantenimiento para Servidor Cisco APIC M4. Cisco APIC M4 46 páginas.

Cisco APIC M4 Manual de instalación y mantenimiento

Power Cord Specifications

Power supply standby voltage
Efficiency rating
Form factor
Input connector
Power Cord Specifications
Each power supply in the server has a power cord. Standard power cords or jumper power cords are available
for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional
alternative to the standard power cords.
Note
Table 11: Supported Power Cords
Description
CAB-48DC-40A-8AWG
DC power cord, -48 VDC, 40 A, 8 AWG
Three-socket Mini-Fit connector to three-wire
CAB-C13-C14-AC
AC power cord, 10 A; C13 to C14, recessed receptacle
CAB-250V-10A-AR
AC power cord, 250 V, 10 A
Argentina
CAB-C13-C14-2M-JP
AC Power Cord, C13 to C14
Japan PSE Mark
CAB-9K10A-EU
AC Power Cord, 250 V, 10 A; CEE 7/7 Plug
Europe
CAB-250V-10A-IS
AC Power Cord, 250 V, 10 A
Israel
Cisco APIC M4/L4 Server Installation and Service Guide
40
12 VDC
≥ 92% at 50% load
RSP2
Fixed 3-wire block
Only the approved power cords or jumper power cords listed below are supported.
Length (Feet)
Length (Meters)
11.7
3.5
9.8
3.0
8.2
2.5
6.6
2.0
8.2
2.5
8.2
2.5
Server Specifications