Cisco APIC M4 Installation And Service Manual - Page 44

Browse online or download pdf Installation And Service Manual for Server Cisco APIC M4. Cisco APIC M4 46 pages.

Cisco APIC M4 Installation And Service Manual

Power Cord Specifications

Power supply standby voltage
Efficiency rating
Form factor
Input connector
Power Cord Specifications
Each power supply in the server has a power cord. Standard power cords or jumper power cords are available
for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional
alternative to the standard power cords.
Note
Table 11: Supported Power Cords
Description
CAB-48DC-40A-8AWG
DC power cord, -48 VDC, 40 A, 8 AWG
Three-socket Mini-Fit connector to three-wire
CAB-C13-C14-AC
AC power cord, 10 A; C13 to C14, recessed receptacle
CAB-250V-10A-AR
AC power cord, 250 V, 10 A
Argentina
CAB-C13-C14-2M-JP
AC Power Cord, C13 to C14
Japan PSE Mark
CAB-9K10A-EU
AC Power Cord, 250 V, 10 A; CEE 7/7 Plug
Europe
CAB-250V-10A-IS
AC Power Cord, 250 V, 10 A
Israel
Cisco APIC M4/L4 Server Installation and Service Guide
40
12 VDC
≥ 92% at 50% load
RSP2
Fixed 3-wire block
Only the approved power cords or jumper power cords listed below are supported.
Length (Feet)
Length (Meters)
11.7
3.5
9.8
3.0
8.2
2.5
6.6
2.0
8.2
2.5
8.2
2.5
Server Specifications