6.3.8 Technical Support Menu

Selecting Technical Support displays Technical support contact information and the software revision.

6.3.9 Rotate Display

Selecting Rotate display will flip the display 180°

7 Installation

Be sure all power is turned off to the operator before
starting installation.
The ECI 1000U LCD board replaces three different
boards. Follow the appropriate procedure for the board
being replaced.

7.1 Replacing the ECI Canada ECI-1001-1300 with ECI 1000U LCD

1. Switch power to the door operator off and wait for the capacitors to discharge.
2. Remove the cover to access the door board
3. Unplug all connectors from the existing board.
4. Unscrew the four nuts holding the existing board in place and remove board.
5. Install the ECI 1000U LCD board and secure board in place.
6. Plug in all connectors
7. Connect the ground wire to X13 pin 1 ( unlabeled pin) of ECI 1000U LCD board
8. Ensure the TEST/RUN switch is in the TEST position and the OPEN/CLOSE and
NUDGE/LOCK switches are in center positions.
9. Perform Section 8 Initial Power up and Adjustments

7.2 Replacing the ECI Canada ECI-1000-500 with ECI 1000U LCD board

1. Switch power off to door operator and wait for capacitors to discharge
2. Remove cover to access door board.
3. Unplug connectors from existing board.
4. Disconnect L1A and L2A from existing board and connect to X12 (2 pin connector) for the ECI
1000U LCD board.
5. Disconnect all wires from J2 (old board) and connect to X13 (7 pin connector) for ECI 1000U
LCD board: DO3, DO10, D07, D04, DO18, DO17.
6. Remove 0V yellow wire form J4 connector (old board) and connect to 0V pin of 6 pin connector
for ECI 1000U LCD board.
7. Remove RB1, RB2, A1, A2 from old board and connect to 6 pin connector for those same
signals of the ECI 1000U LCD board.
8. Disconnect –VS from the old board and remove the old board.
ECI 1000-U LCD Installation Manual
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
www.eciamerica.com