5)
The file of settings can be uploaded into the ECKey EK6 Management Application for viewing and can be exported to other formats.
Retrieve Settings from EK6
1)
Download the Command File to retrieve the settings and/or audit log (see above).
2)
Enter Administration Mode (see above).
3)
Send the Command File to retrieve the settings to ECKey (see above).
4)
Accept the file from ECKey of the settings.
5)
Transfer settings text file to computer with the Management Application via email or Bluetooth.
6)
Import the settings into the Management Application to view.
Delete or blacklist a phone
1)
Remove their access rights from the access control system.
Status Light
Status Light
Off
Red
Green
Solid Blue
Quickly flashes blue
Repeating triple flashes
Repeating quadruple flashes
Repeating eight flashes
Wiring Options
Wire
Description
Red
AC/DC Power Supply (V+)
Black
Ground (G)
Green
Reserved
White
Reserved
Yellow
Relay Common (C)
Blue
Relay N/C (NC)
Brown
Relay N/O (NO)
Orange
External Light (L)
Grey
External Button (B)
Purple
Green LED (EK6-0D only)
Pink
Red LED (EK6-0D only)
Tan
AC Input 2
Functions in the Management Application
Button
Add Site
Create a new site.
Add Phone
This does not add phone to the ECKey unit. This using the settings of the ECKey reader to display the Wiegand number that the readers will generate at this
site for a specific phone. Once the virtual Wiegand card number has been determined for a phone it can be cut and paste into the access control system and
access rights assigned. This requires Bluetooth on the PC.
Note that the virtual Wiegand card number can also be obtained from the access logs of the access control system or through the card enrolment process of
the access control system using an ECKey reader.
Add Reader
This is creates a new reader for this site. All readers within a site generate the same Wiegand card numbers for each phone, though they may have different
settings (range, PIN trigger, etc) associated with each reader.
Save
Saves the settings of the site or reader to the PC database.
.
Delete
Deletes the reader or site.
Set clock
Sets the clock of the ECKey unit used for day and night configuration.
Get settings
Reads the configuration settings from ECKey via command file, Bluetooth or USB cable.
Meaning
Not operating, check power supply
Lock or closed and searching for phones
Unlocked by access control system
Sending Wiegand Message or confirming deleting/reset
ECKey pairing with a phone or available to be discovered by phones to register them.
ECKey available to be discovered for file and management application administration.
Pending deletion of all phones
Pending factory reset
Connect to
12 to 24V DC in the EK3. 12 to 24V DC/AC in the EK4
Ground power supply
Ground of external light, external button, trigger sensor, door position sensor and trigger sensor
Data 0
Data 1
Input for the relay
Connected to the Relay Common when the message is sent.
Connected to the Relay Common when the message is sent.
Positive of the External Light. The external light is the same as the Blue status light.
One side of an external Administration Button. Ground is the other side.
Force the Administration Light Green by connecting to ground by the access control system to indicate unlocked.
Force the Administration Light Red by connecting to ground by the access control system to indicate failure or locked.
N/A