Aeotec ZWA005 Manual - Página 3
Navegue en línea o descargue pdf Manual para Accesorios Aeotec ZWA005. Aeotec ZWA005 8 páginas. Trisensor
1)
Motion Retrigger Time
This parameter is configured the delay time before PIR sensor can be triggered again to
reset motion timeout counter. Value = 0 will disable PIR sensor from triggering until motion
timeout has finished.
Parameter Number
1
2)
Motion Clear Time
This parameter is configured the time to clear motion event after a motion event detected.
Time to motion clear, the device will send a clear event report to controller and send BASIC_SET
= 0x00 to nodes associated in group 2. Unit: Second.
Parameter Number
2
3)
Motion Sensitivity
This parameter is configured the sensitivity that motion detect.
0 – PIR sensor disabled.
1 – Lowest sensitivity.
11 – Highest sensitivity.
Parameter Number
3
4)
Binary Sensor Report Enable
'0' –Disable sensor binary report when motion event is detected or cleared.
'1' –Enable sensor binary report when motion event is detected or cleared.
Parameter Number
4
5)
Disable BASIC_SET to Associated nodes
This parameter is configured the enabled or disabled send BASIC_SET command to nodes
that associated in group 2 and group 3.
0 – Disabled All Group Basic Set Command
1 – Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is
disabled. 2 – Enabled Group 3 Basic Set Command, Group 2 Basic Set
Command is disabled. 3 – Enabled Group 2 and Group 3 Basic Set Command.
Parameter Number
5
Size (Byte)
2
Size (Byte)
2
Size (Byte)
1
Size (Byte)
1
Size (Byte)
1
Available Settings
0 ~ 32767
Available Settings
1 ~ 32767
Available Settings
0 ~ 11
Available Settings
0 , 1
Available Settings
0 ~ 3
Default value
30
Default value
240
Default value
11
Default value
0
Default value
3