Aeotec Smart Switch 7 Manual - Página 17

Navegue en línea o descargue pdf Manual para Interruptor Aeotec Smart Switch 7. Aeotec Smart Switch 7 18 páginas.
También para Aeotec Smart Switch 7: Manual del usuario (8 páginas), Manual (6 páginas)

Aeotec Smart Switch 7 Manual
0
Can be disabled by 3x tapping Action Button within 1 second
1
Can be disabled when receives a State Idle corresponding to the alarm .
Note: If Access Control is enable, it also can be disabled when receives
the reversal state of window/door.
10..255 Sets the duration of the alarm in seconds(i .e. Customer sets this setting
to 50, the alarm state of the Switch will disable after 50 seconds)
Note:
Power off will also disable the alarm response without any limitation.
0x12(18)
LED blinking frequency.
Value
Description
1..9
Set amount of blinks per seconds.
Note:
When receiving the enable Alarm, it will flash according to the blink frequency
configured by this parameter until the Alarm is disable. Brightness level and color
is based on current indicator. If the value of brightness level and color is 0, it will
flash based on last visible color.
0x13(19)
Start or stop LED blinking.(Write Only)
Value
Description
0
Stop blinking.
1..255
Set the duration and start the blinking process .
* This sets the timeframe of blinking in seconds .
* Once the duration ends, the blinking will stop .
Note:
The parameter can be used to test the effect of LED blinking.
0x14(20)
Action in case of power out.
Value
Description
0
Last status
1
Switch is on
2
Switch is off
0x50(80)
Configure what command will be sent via Lifeline when switch state has changed.
Value
Description
0
None
1
Basic Report
2
Binary Switch Report
0x51(81)
Load Indicator Mode setting .
Value
Description
0
Disable Mode.
* LED will only illuminate for network removal, press and hold Action
Button.
* No other LED reaction for load status.
* Will allow LED blinking frequency parameter setting to blink the LED.
* Brightness level can NOT be configured via Multilevel Switch CC.
* Color can NOT be configured via Color Switch CC.
* Will report Application Rejected Request when receives Multilevel
Switch CC or Color Switch CC.
1
Night Light Mode.
* During enable time, 100% Red is the default color and can be
changed.
* During disable time, OFF is the default color and can be changed.
* Enable and disable time are defined by Parameter 0x52(82).
* Brightness level can be configured via Multilevel Switch CC.
* Color can be configured via Color Switch CC.
2
ON/OFF Mode.
* ON status, 50% White is the default color and can be changed.
* OFF status, 10% Green is the default color and can be changed.
* Brightness level can be configured via Multilevel Switch CC.
* Color can be configured via Color Switch CC.
Note:
Configuring brightness and color of Indicator Light in different time/status of
different modes will be saved in the current setting mode .
0x52(82)
Configure the enable and disable time of Night Light Mode
AEOTEC Engineering Specification
Page 12
WR
2
1
W
-
2
WR
0
1
WR
2
1
WR
2
1
WR
0x12000800 4