Aeotec Smart Switch 7 Manual - Página 16
Navegue en línea o descargue pdf Manual para Interruptor Aeotec Smart Switch 7. Aeotec Smart Switch 7 18 páginas.
También para Aeotec Smart Switch 7: Manual del usuario (8 páginas), Manual (6 páginas)
3
Switch will turn ON in 5 seconds, and then turn OFF in 5 seconds in a
cycle until user disables the alarm manually
Note:
When receives any alarm enabled by Alarm Settings, Indicator Light will keep
blinking based on Parameter 0x12 (18). It will prohibit user from manually or RF
control the switch state until the alarm is disable .
0x09(9)
Alarm Settings.
Determine if alarms are enabled in Switch, and what Switch will react to which
alarm. The format of the parameter is Bit field (Checkboxes). The parameter MUST
be treated as a bit field where each individual bit can be set or reset. A graphical
configuration tool SHOULD present this parameter as a series of checkboxes.
7
Value1 Reserved
Value2
Value1: Supported Notification Type and Notification Event
Value
Notification Type
1
Smoke Alarm
2
CO Alarm
4
CO2 Alarm
8
Heart Alarm
16
Water Alarm
32
Access Control
64
Home Security
Value2: Access Control trigger state:
Value
Description
0
Alarm will be triggered by open state, and be disable by closed state or
idle state
1
Alarm will be triggered by closed state, and be disable by open state or
idle state
Example:
If the parameter value equals to 8704(0x2200), Alarm Response will active when
receives Carbon monoxide detected or Window/door is open.
If the parameter value equals to 8705(0x2201), Alarm Response will active when
receives Carbon monoxide detected or Window/door is Closed.
0x0A(10)
Setting to disable alarm.
Determines the method of disabling the alarm of the device.
Value
Description
AEOTEC Engineering Specification
6
5
4
Home
Access
Water
Security
Control
Alarm
Reserved
Notification Event
State idle
Smoke detected (location provided)
Smoke detected
State idle
Carbon monoxide detected (location provided)
Carbon monoxide detected
State idle
Carbon dioxide detected (location provided)
Carbon dioxide detected
State idle
Overheat detected (location provided)
Overheat detected
State idle
Water leak detected (location provided)
Water leak detected
State idle
Window/door is open
Window/door is closed
State idle
Intrusion (location provided)
Intrusion
Motion detection (location provided)
Motion detection
Page 11
3
2
1
Heart
CO2
CO
Alarm
Alarm
Alarm
WR
0
0
Smoke
Alarm
Access
Control
trigger
state
WR
0
2
2