Alemite 6713-4 Manual de servicio - Página 9
Navegue en línea o descargue pdf Manual de servicio para Bomba de agua Alemite 6713-4. Alemite 6713-4 10 páginas. High-pressure bucket pump
High-Pressure Bucket Pump
23. Screw the Coupling Adapter [with Loctite 242] into
the Coupling Nut.
• Tighten the Coupling Nut securely.
24. Screw the Check Valve Assembly [with thread sealant]
[coarse thread first] into the Body.
• Tighten the Check Valve securely.
25. Screw the Adapter Body assembly [with thread sealant
on Check Valve] onto the Check Valve.
• Tighten the Adapter Body securely.
Pump Tube (Continued)
26. Position Handle Assembly (14) properly on Adapters
(16). See Figure 2-B.
27. Hold Spacer (15) between the Adapter and the Handle
Assembly. See Figure 2-B.
28. Install Toggle Bolt (11), Lock Washers (12), and Nut
(13) that secures the Handle Assembly to the Adapters.
• Tighten the Nut securely.
Alemite Corporation
29. Install upper Toggle Bolt (39), Lock Washers (12), and
Nut (13) that secures Toggle (40) to the Handle
Assembly.
• Do not tighten the Nut at this time.
30. Install lower Toggle Bolt (39), Lock Washers (12), and
Nut (13) that secures the Toggle to the Body.
• Tighten both Toggle Nuts securely.
Attach Pump Tube to Cover
NOTE: Refer to Figure 2-A for component
identification on the following procedures.
31. Install Seal (10) onto the Drain Tube.
32. Install Nuts (5) Lock Washers (6), and Screws (8) that
secure the Pump Assembly to Cover Assembly (9).
• Tighten the Screws securely in a crisscross pattern.
9
SER 6713-4
Revision (2-02)