If your HA pair is running a version of ONTAP 9.6, you need to reboot the
controllers, one at a time.
If your HA pair is running ONTAP 9.7 or later, you do not need to reboot the
controllers, unless one or both controllers are in maintenance mode. This
procedure assumes that neither controller is in maintenance mode.
Steps
1. Verify if the non-dedicated ports in the HA pair are configured for storage use:
show
You can enter the command on either controller module.
If your HA pair is running ONTAP 9.8 or later, the non-dedicated ports display
Mode
column.
If your HA pair is running ONTAP 9.7 or 9.6, the non-dedicated ports, which display
Is Dedicated?
column, also display
2. If the non-dedicated ports are configured for storage use, you are done with this procedure.
Otherwise, you need to configure the ports by completing steps 3 through 6.
When non-dedicated ports are not configured for storage use, the command
output displays the following:
If your HA pair is running ONTAP 9.8 or later, the non-dedicated ports display
network
If your HA pair is running ONTAP 9.7 or 9.6, the non-dedicated ports, which
display
State
3. Configure the non-dedicated ports for storage use, on one of the controller modules:
You must repeat the applicable command for each port you are configuring.
If your HA pair is
running...
ONTAP 9.8 or later
ONTAP 9.7 or 9.6
4. If your HA pair is running ONTAP 9.6, reboot the controller module so that the port changes
system node reboot -node node name -reason reason for the reboot
take effect:
enabled
in the
Mode
in the
column.
false
Is Dedicated?`
in the
column.
Then...
storage port modify -node node name -port port name -mode
storage
storage port enable -node node name -port port name
State
column.
column, also display
storage port
storage
in the
false
in the
disabled
in the
3