CAME ZL19N Manual de instalación - Página 4
Navegue en línea o descargue pdf Manual de instalación para Abrepuertas de garaje CAME ZL19N. CAME ZL19N 17 páginas. Control panel for 24v gearmotors

4.2 Main components
1.
Transformers
2.
Speed adjuster connectors
3.
Terminal board for connecting the
002LB18 card (if unused, make sure that
bridges are connected among A-B;C-D;
E-F; G-h)
4.
Accessories fuse
5.
Card fuse
6.
Amperometric sensitivity during travel
adjustment trimmer
7.
Amperometric sensitity during travel
adjustment trimmer
8.
Amperometric sensitivity during
slowdown adjustment trimmer
9.
Opening / closing strike zone adjustment
trimmer
10.
Automatic closing adjustmet trimmer
11.
M2 closing delay adjstement trimmer
12.
10-Dip switch selector function
13.
LED to signal radio code/ ACT counter
14.
Code memorising buttons
15.
Selection jumper B1-B2 / cycle lamp
16.
Radio frequency card socket
17.
Line fuse
18.
Connection terminals
19.
4-Dip switch function selector
20.
Selection jumper for command type for
button on 2-7
21.
Electro lock fuse
22.
M1 motor fuse
23.
M2 motor fuse
5 Installation
Installation must be carried by skilled, qualified technicians in accordance with current regualtions.
5. 1 Preliminary checks
Before beginning to install, the following is necessary:
• Check that the fastening point of the control panel is protected from accidental impacts, and that the surfaces used for fastening are
solid, and that the fastening is done with proper screws, plugs.
• Set up a suitable omnipolar cut-off device, with distances greater than 3 mm between contacts, with sectioned power source
•
Check that any connections inside the container (made for continuity purposes of the protective circuit) are fi tted with extra
insulation compared to other internal conductive parts.
• Set up proper conduits and electric cable raceways, making sure these are protected from any mechanical damage.
23
22
20
12
17
13
Warning! Before acting on the eqipment, cut off the main power supply and disconnect
the emergency batteries (if present).
2
4
21
3
1
6
7
9
10
11
14
18
5
8
19
16
15