esera automation ECO 10 Manual del usuario - Página 3
Navegue en línea o descargue pdf Manual del usuario para Controlador esera automation ECO 10. esera automation ECO 10 13 páginas. 1-wire controller
Art. No. 11601-24
2
Auto-E-Connect Support
The ECO 10 1-Wire Controller supports Auto-E-Connect Level I and II.
Auto-E-Connect Level III is supported from the ECO 100 series onwards.
3
Auto-E-Connect System
With the launch of the ECO controllers, the ESERA Auto-E-Connect® 1-Wire Plug and Play system for the
1-Wire Bus is now introduced and supported.
This means that fully automatic configuration of the 1-Wire Devices* (sensors and actuators) on the 1-Wire
Bus is now possible.
It is optimised for commercial and industrial applications and enables significant added value beyond sensor
and chip data.
The Auto-E-Connect function is built up in three levels. Currently there are Level I, Level II and Level III
available.
With Auto-E-Connect Level III, fully automatic configurations of the 1-Wire Devices on the
1-Wire Bus are possible. It is optimised for industrial and IoT applications and enables significant added
value beyond sensor and chip data.
With the Auto-E-Connect function, ESERA Devices are recognised fully automatically, suitable libraries are
started and ready-formatted data is output.
The Auto-E-Connect functionality will be available for the ECO Controller and ESERA-Station 200 Pro from
2021.
Auto-E-Connect Level I
OWD Detect: detection of new sensors* and actuators* and automatic start of adapted libraries
Auto-E-Connect Level II
Visualisation product data: read out and visualise the Auto-E-Connect and manufacturer data of sensors* and
actuators*, e.g. article number, date of manufacture, firmware and hardware version.
Auto-E-Connect Level III, not ECO 10, only supported from ECO 100 PRO onwards.
Extended Plug and Play System for 1-Wire Bus
o
Pre Configuration: The OWD number for the next installation can be written to the 1-Wire Device*.
o
Automatic Positioning: The Device* logs on to each ECO Controller with Auto-E-Connect III with the new
desired OWD number. This automatic login works up to the maximum possible OWD number of the ECO
Controller.
o
Sensorfinder Function: The ECO 10 can activate a status LED within the ESERA 1-Wire Pro sensors*. The
status LED flashes or lights up permanently for a certain time. This makes it much easier to detect a device
in a 1-Wire Network. Faster detection saves a lot of time and therefore money when searching for a 1-Wire
Device.
o
Classes Assignment: ESERA 1-Wire Devices are assigned to OWD classes with the same properties. This
assignment enables fully automatic visualisation and data evaluation in control systems. A class list is
available from ESERA.
For further information on the ESERA Auto-E-Connect system, please refer to the ESERA website and the
ESERA Config Tool 3.
Auto-E-Connect is registered by ESERA GmbH as a German and European Patent.
* if the sensor or actuator supports Auto-E-Connect. For details, please refer to the operating instructions of the sensor or actuator.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH 2021
www.esera.de
11601-24 V1.0 R1.1 Manual
Page 3 of 13