AIO 2510-SXT Manual de instalación y puesta en marcha - Página 7
Navegue en línea o descargue pdf Manual de instalación y puesta en marcha para Sistema de agua AIO 2510-SXT. AIO 2510-SXT 7 páginas. Iron air charge
Iron Air Charge 2510-SXT Installation & Startup Guide
Bypass Assembly
The system must be backwashed once upon startup. First, put the system into service mode.
Normally the system ships in the bypass position. Once the system is properly plumbed in, make
sure to turn both of the bypass valve knobs 90 degrees into service mode.
Regeneration Cycle (59 minutes)
1. Backwash (14 minutes) During this cycle, the water carrying the iron runs to the drain. Untreated
water is available during regeneration.
2. Air Recharge (40 minutes) during this cycle, the unit empties water to the drain and is recharged
with air. The sound of air being recharged will be heard. Air bubbles should go down to the drain
before proceeding to the next step. Adjust cycle time if necessary.
3. Rapid Rinse (5 minutes) During this cycle, water enters the tank, compressing the air into a pocket
at the top of the tank.
4. Brine Refill (Off)
5. Unit Returns to the In-Service Position
The frequency and time of regeneration can be changed due to the following reasons.
• In conditions of high water usage and/or high levels of iron, the unit may need to regenerate more
frequently than once every three days. The unit can be set for daily regeneration or to regenerate
every two days. DO NOT set the regeneration frequency for a longer period than 3 days, as the
filter medium can become fouled with iron, rendering the unit ineffective.
REV 070914
Page 6