ACR STOVES NOVUS Manuel technique - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel technique pour {nom_de_la_catégorie} ACR STOVES NOVUS. ACR STOVES NOVUS 17 pages.

Novus manual 0916-1 24/11/2016 13:43 Page 6
This appliance is equipped with a pre-fitted manufacturers smoke exempt stop. Under
no circumstances should it be tampered with or removed unless expressly authorised
by a competent person and the appliance is not installed in a smoke exempt area.
If the appliance is to be installed in a non smoke exempt area you can remove the
restricting screw on the air control wheel to allow full movement.
The appliance is supplied pre-assembled with the flue spigot in the top exit
position.
• If using a top exit flue connection please ensure that the ceramic top casting is
fitted BEFORE the flue connection is made.
If you intend to install the appliance using a rear flue connection, the blanking
plate should be swapped over as follows:
A
B
Heat shield installation:

Assembly of the unit

• Remove the outer blanking plate
• Remove the inner blanking plate
two bolts
• Remove the flue spigot from the top exit by removing
the securing bolts and rope seal
• Refit the rope seal and flue spigot to the rear exit and
secure with the bolts.
• Refit the blanking plate to the top exit using the rope
seal and retaining bolts.
• Insert cosmetic ceramic blanking plate into the
ceramic top recess
• Please fit the included heat shield (see
attached diagram).
The heat shield must be fitted on all
installation occasions without exception.
A
in the rear panel
B
by removing the