INSTALL HANDLES

• Turn hot and cold VALVE STEMS (1) to the off position.
• Push ADAPTER (2) onto VALVE STEM (1), so the recess in ADAPTER (2)
is facing toward the back wall. VIEW "A". Install and tighten STEM
SCREW (3) to secure ADAPTER (2).
• Align the hole in back of the HANDLE (4) with the recess in ADAPTER (2).
Install the HANDLE (4) onto ADAPTER (2).
• Tighten SET SCREW (5) with 5/64" HEX WRENCH (6) supplied.
6
SERVICE
To change direction of handle rotation, proceed as follows:
• Turn valve to OFF position.
• Loosen handle set screw to remove HANDLE (2) from HANDLE ADAPTER (3).
• Loosen the adapter screw (4). Use a flat blade screw driver to remove
SPRING CLIP (5).
• Lift STOP WASHER (6), turn 90˚ and replace.
• Replace SPRING CLIP (5).
• Reinstall HANDLE ASSEMBLY (2) and tighten set screw.
• If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
6a
SERVICE — TO REMOVE DIVERTER
• Turn off the water supplies.
• Turn HANDLE to the off position.
• Remove the HOLDER by threading it counter clockwise.
• Remove the SLEEVE from DIVERTER by loosening screw.
• Using 14 mm (9/16") Deep Socket, remove diverter.
3
- 3 -
4
5
HOLE IN BACK
OF HANDLE
VIEW "A"
RECESS IN BACK
OF ADAPTER
2
1
VIEW "A"
1
HOLE IN BACK
OF HANDLE
4
3
90˚
6
5
HOLDER
SCREW
DIVERTER SLEEVE
DEEP SOCKET
14 mm (9/16")
DIVERTER
M965798 Rev. 1.0 (3/17)
6
2
"
5/64
HEX
WRENCH