FIREBOX FINISHES

There are a wide variety of "finished looks" for your built-in Vent-Free
firebox from formal wall decor with elaborate mantels to rustic wood
paneling or warm brick facings.
Only noncombustible materials like marble, stone, tile, brick, etc. may
overlap the black front facing. Seal all joints between the black facing
* From Base to Bottom of
Firebox Opening (floor)
Figure 23 - Raised Hearth Extension
Combustible Wall
Non-Combustible Wall
(see Figure 4)
Raised Hearth Extension
(combustibles allowed.
No carpet or vinyl)
5-3/4" Max.*
Combustible Platform
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
and wall surrounds to prevent air intrusion. Use noncombustible caulking
material only to seal the black metal facing to the surround material on
the finished wall. See Figures 3 and 23.
Raised Hearth Extension
A hearth extension may be used but is not required for these appliances.
A raised hearth extension may be used as shown in Figure 23.
Fireplace Opening
Firebox Floor
Base
SIDE VIEW