The CB Manual thermostat control a floor heating system based on a built-in weekly program. You can set
individual temperatures for 4 events or 2 events on different days of the week. The default weekly program
parameters can satisfy most installations. If your living habits are different, you can update the weekly
program parameters in the thermostat or APP. Lowering the temperature when the home is
unoccupied will reduce your energy costs without reducing comfort. Furthermore, the thermostat features
an adaptive function that automatically changes heating period start times to ensure that the required
temperature is reached at the required time. After some days the adaptive function has learned when the
heating must be switched on.
Technical Specification
Supply voltage:
85-265 VAC 50/60 Hz
Load:
Max.16 A (resistive load)
Standby Power Loss: <1W
Cable Diameter:
1. Loosen the bottom screw with a Phillips
screwdriver. Then open the thermostat from
the right corner as shown.
Note: Screw the nut out of the groove. No need
to unscrew it
2. Wire as shown:
L/N lead:
Connect the power cord
using the terminal block.
Use a terminal block to
connect the load line.
L1/N1 lead:
Use a terminal block to connect the
load line.
COM/S1 terminal: Connect the floor sensor.
Note: Disconnect the main power supply before wiring
3. Install the back cover into the terminal box and
secure it with the set screw.
4. Install the back cover into the terminal box and
secure it with the set screw.
≤2.5mm²