Expand Serial Command Functional Specification

8.10.2. CF_MUTE Command

Command
"CF_MUTE_%1" [CR]
"ON" --------- Sound Mute On
%1
"OFF" -- ----- Sound Mute Off
Details
Control Sound Mute On/Off. (Only valid when it is in the usual Power On status)
Acceptable
Response
Unacceptable

8.11. Setting Command

8.11.1. CF_BBACK Command

Command
"CF_BBACK_%1" [CR]
"ON" --------- Set Blue Back
%1
"OFF" -- ----- Cancel Blue Back
Set / Cancel Blue Back. (Only valid when it is in the usual Power On status)
Details
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
Response
Unacceptable

8.11.2. CF_DISP Command

Command
"CF_DISP_%1" [CR]
"ON" --------- Set Display
%1
"OFF" -- ----- Cancel Display
Set / Cancel Display. (Only valid when it is in the usual Power On status)
Details
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
Response
Unacceptable

8.11.3. CF_LOGO Command

Command
"CF_LOGO_%1" [CR]
"OFF" ------------------ Cancel Logo
%1
"DEFAULT" ---------- Set Default Logo display
"USER" ---------------- Set Captured Logo display
Set / Cancel Logo. (Only valid when it is in the usual Power On status)
Details
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
Response
Unacceptable

8.11.4. CF_CEIL Command

Command
"CF_CEIL_%1" [CR]
"ON" ---------- Select Ceiling
%1
" O F F " - -- - - -- - Cancel Ceiling
Set / Cancel Ceiling. (Only valid when it is in the usual Power On status)
Details
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
Page 23 of 41