7.8. Temp Read Command

Command
"CR6" [CR]
Get the temperature data inside the projector.
Detail
With some temperature sensors installed in the projector, it is possible to get all
the temperature at once.
Acceptable
Response
Unacceptable

7.9. Lamp Mode Read Command

Command
"CR7" [CR]
Get lamp mode status.
Detail
For 1 lamp projector, get if it is lighting or not.
Acceptable
Response
Unacceptable
"%1_%2_%3" [CR]
%1 Temperature of sensor 1
%2 Temperature of sensor 2
%3 Temperature of sensor 3
Temperature data is shown as "00.0".
When the temperature goes down to -, the first character
%1
becomes "-" instead of a space, like "-05.5" [CR].
%2
When no temperature data can be returned due to hardware
%3
problems, the first character becomes "E" like"E00.0" [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
"_31.5 _ _35.2 _ _33.4"[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.
" "[CR]
"%1" [CR]
"00" [CR]=Light is out.
%1
"01" [CR]=Light is on.
" "[CR]