Canon LV-8320 사양 - 페이지 26
{카테고리_이름} Canon LV-8320에 대한 사양을 온라인으로 검색하거나 PDF를 다운로드하세요. Canon LV-8320 26 페이지. Lv series multimedia lcd projectors
Canon LV-8320에 대해서도 마찬가지입니다: 사양 (2 페이지)
7.8. Temp Read Command
Command
"CR6" [CR]
Get the temperature data inside the projector.
Detail
With some temperature sensors installed in the projector, it is possible to get all
the temperature at once.
Acceptable
Response
Unacceptable
7.9. Lamp Mode Read Command
Command
"CR7" [CR]
Get lamp mode status.
Detail
For 1 lamp projector, get if it is lighting or not.
Acceptable
Response
Unacceptable
"%1_%2_%3" [CR]
%1 Temperature of sensor 1
%2 Temperature of sensor 2
%3 Temperature of sensor 3
Temperature data is shown as "00.0".
When the temperature goes down to -, the first character
%1
becomes "-" instead of a space, like "-05.5" [CR].
%2
When no temperature data can be returned due to hardware
%3
problems, the first character becomes "E" like"E00.0" [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
"_31.5 _ _35.2 _ _33.4"[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.
" "[CR]
"%1" [CR]
"00" [CR]=Light is out.
%1
"01" [CR]=Light is on.
" "[CR]
-23-
LV-8320 Basic Serial Command Specifications