4.2 Service inspection of the PacMobile 20
The following points must be checked regularly:
•
Internal RCM need to be tested on correct functioning on a regular basis. During the yearly
maintenance visit, a check is advised, to be executed by a certifi ed ABB technician.
•
Cable and connector
Check for cracks or ruptures on the connector or cable, check whether no internal wires of the
cable are visible.
•
Display screen
Check for damage and cracks.
•
Powder coating
Look for damage, cracks or ruptures.
4.2.1 Special inspections
In the following cases the PacMobile 20 must be checked by ABB service personnel before further use:
•
If it was struck by lightning.
•
If it is damaged due to an accident or fi re.
•
If its location has been fl ooded.
Do not power on until the charger has been inspected and approved.
4.3 Problem resolving
The site operator or helpdesk is the fi rst response to a customer call. The helpdesk can remotely solve
simple problems for the customer.
In special cases the site operator with knowledge of the charger can be asked by ABB Service to report
about the status of some internal components of the charger. Therefore, a brief description of the position
and function of these components is described on the next pages.
4.3.1 Overview of the enclosure
A. HMI touch-screen display
B. Bottom cover
C. Fixing screws (2x)
The bottom cover can be opened by removing the
two fi xing screws (C) with a screwdriver.
A
B
C
15