Baumer GIM500R Manuel - Page 19

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Baumer GIM500R. Baumer GIM500R 20 pages. Inclination sensors
Également pour Baumer GIM500R : Manuel (29 pages), Manuel (13 pages), Instructions de montage (2 pages)

Baumer GIM500R Manuel
Terminals with the same designation are internally hardwired and identical in their functions. Maximum load
applied on Vs-Vs / GND-GND is 1 A each.
Cable wires
Wire
Assignment
white
+Vs
brown
GND
green
OUT_X
yellow
OUT_Y
grey
Teach
pink
d.u.
blue
d.u.
red
A_GND
Wires with the same designation are internally hardwired and identical in their functions. Maximum load
applied on Vs-Vs / GND-GND is 1 A each.
Baumer_GIM500R_Analog_MA_EN.docx
11.04.18
Description
Voltage supply
Ground connection relating to +Vs
Output
Output
Teach input
Do not use
Do not use
Ground connection related to analog
19/20
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany