Terminals with the same designation are internally hardwired and identical in their functions. Maximum load
applied on Vs-Vs / GND-GND is 1 A each.
Cable wires
Wire
Assignment
white
+Vs
brown
GND
green
OUT_X
yellow
OUT_Y
grey
Teach
pink
d.u.
blue
d.u.
red
A_GND
Wires with the same designation are internally hardwired and identical in their functions. Maximum load
applied on Vs-Vs / GND-GND is 1 A each.
Baumer_GIM500R_Analog_MA_EN.docx
11.04.18
Description
Voltage supply
Ground connection relating to +Vs
Output
Output
Teach input
Do not use
Do not use
Ground connection related to analog
19/20
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany