3.3.6.1 Heartbeat protocol
Example for a heartbeat protocol
COB-ID
Data/Remote
701h
d
The heartbeat messages consist of the COB-ID and one byte. In this byte, the NMT status is supplied.
0:
Boot Up-Event
4:
Stopped
5:
Operational
127:
Pre-operational
In other words, the sensor is in the pre-operational state (7Fh = 127).
3.3.6.2 Layer Setting Services
In 2000, CiA drafted a new protocol intended to ensure standardized occurrence. The procedure is described
under Layer Setting Services and Protocol, CiA Draft Standard Proposal 305 (LSS).
The sensor is supplied as standard with node-ID 1 and baud rate 50 kbits/s. Several sensors can be con-
nected to the bus system with the same node-ID. To allow individual sensors to be addressed, LSS is used.
Each sensor is fitted with its own unique serial number and is addressed using this number. In other words,
an optional number of sensors with the same node-ID can be connected to one bus system, and then initial-
ized via LSS. Both the Node-ID and also the baud rate can be reset. LSS can only be executed in the
Stopped state.
Message structure
COB-ID:
Consumer  Producer : 2021 = 7E5h
Consumer  Producer : 2020 = 7E4h
After the COB-ID, an LSS command specifier is transmitted.
This is followed by up to seven attached data bytes.
Baumer_GIM700DR_CANopen_EN_V1.00_MNL.docx
27.04.21
Byte 0
7Fh (127d)
14/32
A Heartbeat Producer transmits the
Heartbeat message cyclically with the
frequency defined in Heartbeat producer
time object. One or more Heartbeat Con-
sumer may receive the indication. The re-
lationship between producer and con-
sumer is configurable via Object Diction-
ary entries. The Heartbeat Consumer
guards the reception of the Heartbeat
within the Heartbeat consumer time. If
the Heartbeat is not received within this
time a Heartbeat Event will be generated.