Baumer GNAMG Series Manuel - Page 27
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Baumer GNAMG Series. Baumer GNAMG Series 41 pages. Inclination sensor with canopen interface
Object 2110
Manufacturer_Options
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Object 2201
Statistics
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Manual_GNAMG_CANopen_EN.doc
21.11.12
0
Unsigned 32
ReadWrite
8h
Yes
Parameters to guarantee compatibility to former sensors respectively to
proceed customer-specific configurations
Object is not supported by EDS file.
Any parameterization should be by the manufacturer only. Any customer-
specific parameterization should be strictly conform to the table below.
Bit3 = 0 no reset if BusOFF
1 bus reset if BusOFF
Bit5 = 0 Heartbeat protocol active
1 Nodeguarding protocol active
0
Unsigned 8
ReadOnly
3h
No
Maximum supported subindex
3
1
Unsigned 32
ReadOnly
0h
Yes
Presently not assigned
-
2
Unsigned 32
ReadOnly
0h
Yes
Operating time in seconds total (object 6508h time elapsed since last reset)
0... 4294967295
3
Unsigned 32
ReadOnly
0h
Yes
WatchDog TimerReset counter
0... 4294967295
27/41
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany