Electric Co WDH-610HA Manuel - Page 14

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Electric Co WDH-610HA. Electric Co WDH-610HA 19 pages.

Electric Co WDH-610HA Manuel
Problem
The fan and the
compressor are not
working
Not collecting
water
Noise emission
during usage
Frozen condenser
Water leakage
CLEANING
Air Filter
- The air filter must be regularly cleaned. This filter is behind the air inlet grid (B).
Note: for a daily use, the filter should be cleaned once a week.
- To remove the filter, remove the tank (A) and tip the appliance towards the rear at an
angle of approximately 15º. Hold the filter and pullet downwards (Fig. 4).
- Clean the air filter with water and place is back on the appliance.
Note: it is not necessary for the filter to be completely dry when you replace it in the
appliance.
14
Possible Cause
The appliance has no power
Motor failure
Electronic fault
Air inlet filter blocked
Low level of refrigerant gas
Temperature and humidity are
too low
The surface where the
appliance is placed is irregular
Dirty air filter
Temperature is too low
Drainage tank (A) is not fitted
correctly
Micro switch failure
Frozen appliance
Solution / Hint
Check that if the appliance's
plug is properly connected to
a wall socket.
Check if the wall socket is
damaged.
Go to the store where the
appliance was bought.
Go to the store where the
appliance was bought.
Clean the air filter.
Go to the store where the
appliance was bought.
Turn off the appliance and
wait for the temperature to
rise.
Place the appliance on a flat
a stable surface.
Clean the air filter.
Turn off the appliance and
wait for the temperature to
rise.
Fit the drainage tank (A)
properly.
Go to the store where the
appliance was bought.
Turn off the appliance and
wait until the ice defrosts.