Baumer CANopen HMG 10 Manuel d'installation et d'utilisation - Page 12

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Baumer CANopen HMG 10. Baumer CANopen HMG 10 36 pages. Absolute encoder with magnetic sensing

MOUNTING / MOUNTING TO DRIVE SHAFT
4.3.2
Version with cone shaft
)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder�
» Lubricate drive shaft!
)
Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
9/33
12�
10b
10c
10a
5
10e
10d
10c 10b
10b
9
10c
1�6x8 mm
MB250EN - 11173966, 17A2, Baumer_HMG10-CANopen_II_EN
17 mm
7a
11b
11a
Mt = 3-4 Nm
10 mm
section 4.5,
TX 20
2
3
5 mm