User Sets
8.6.
Three user sets (1-3) are available for the Baumer cameras of the SXC series. The user
sets can contain the following information:
Parameter
Binning Mode
CameraLink
Control
®
Defectpixellist
Digital I/O Settings
Exposure Time
Gain Factor
Look-Up-Table
These user sets are stored within the camera and and cannot be saved outside the de-
vice.
By employing a so-called "user set default selector", one of the three possible user sets
can be selected as default, which means, the camera starts up with these adjusted pa-
rameters.
8.7.
Factory Settings
The factory settings are stored in an additional parametrization set which is used by de-
fault. This settings are not editable.
Parameter
Mirroring Control
Offset
Partial Scan
Pixelformat
Readout Mode
Testpattern
Trigger Settings
37