Follett 25HI425A Manuel d'installation - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Follett 25HI425A. Follett 25HI425A 17 pages. Ice and water dispensers
Electrical
§ 115 V, 60 Hz, 1 phase, 11.0A
§ Connect to a 15A dedicated circuit.
§ Furnished with 7 ft (2 m) power cord with a 90° NEMA hospital grade 5-15 plug.
Ambient
Air temp*
Water temp
†
Water pressure (psi/bar)
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
Ambient water temperature is measured in the ice machine float reservoir.
†
Plumbing
Dispenser drain
Water inlet
Condenser inlet
Condenser outlet
Note: Water shut-off recommended within 10 ft. (3m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
Required for ventilation
Suggested for service
Note: Do not block right side air intake or right side air exhaust.
Dry weight
§ 25/50CI425A/W (countertop): 215 lbs. (98 kg)
§ 25/50HI425A/W (wall mount): 230 lbs. (105 kg)
100 F/38 C Max.
50 F/10 C Min. (Best performance below 80 F (27 C)
90 F/32 C Max.
45 F/7 C Min. (Best performance below 70 F (21 C)
70/5 Max.
10/0.7 Min.
Connections 25/50CI425A
Water-cooled 3/8" FPT
Water-cooled 3/8" FPT
3" (77 mm) each side
12" (30.5 cm) top,
6" (15.3 cm ) left side
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
Rough-ins 25/50HI425A
3/4" MPT
3/8" FPT
Air-cooled
Air-cooled 3/4" FPT
3/8" FPT
N/A
N/A
Water-cooled
N/A
12" (30.5 cm) top
3