Reversing the Door Swing – Optional
When reinstalling latch and hinge screws, 242 blue Loctite* or PERMA- LOK
MM115 MUST be applied to screws. Torque screws to 4.6 Nm.
1. Remove screws and latch from refrigerator cabinet (Fig. 4.1).
2. Use flat screwdriver to carefully remove (do not scratch) hinge
covers (Fig. 5.1).
3. Support door and remove screws attaching hinge to refrigerator cabinet
(Fig. 5.2).
4. Cover hinge screw holes with screw hole plugs removed from
opposite side.
5. Reverse door. Apply 242 blue Loctite or PERMA-LOK MM115 to hinge
screws and reinstall torqued to 4.6 Nm.
6. Reinstall latch on opposite side.
7. Remove screws and handle from door (Fig. 6.1).
8. Rotate handle (Fig. 6.2).
9. Apply 242 blue Loctite or PERMA-LOK MM115 to latch screws and
reinstall torqued to 4,6Nm (25 in-lbs.).
Note: Refer to Keypad Lock Operation and Service Manual
(# 00962928) for reversing a door equipped with a keypad lock.
*Loctite is a registered trademark of Henkel Corporation in the United States and other countries.